Include this script into your page along with the iframe for a responsive media embed
In this case the client ran out of adblue and even after refilling. The car still refused to start until a reset was preformed. - Select control module #1 engine - Select long adaptation - Choose channel #80 - Enter 001, to preform reset - The Adblue has to be filled 100% for this to work - After the value changes to 4 the reset is completed If you live in the Greater Toronto Area, Ontario Canada and are interested in coding/adaptations services. Please Contact me at www.trackready.ca/new-page www.trackready.ca/coding